DENG Linghui, WANG Junmin, CHEN Shengguang, et al. Effect of layout mode on abnormal large displacement of power pipeline[J]. Thermal power generation, 2021, 50(4): 120-125.
DOI:
DENG Linghui, WANG Junmin, CHEN Shengguang, et al. Effect of layout mode on abnormal large displacement of power pipeline[J]. Thermal power generation, 2021, 50(4): 120-125. DOI: 10.19666/j.rlfd.202007227.
Effect of layout mode on abnormal large displacement of power pipeline
When the actual load of hangers on the power pipe in service deviates from the design load
some pipelines have abnormal large displacement as the load transfer occurs. To solve this problem
finite element analysis software was applied to calculate the cold and hot displacements of the pipeline with different layout schemes under conditions with the same wall thickness deviation and performance of hangers. The results show that
the abnormal large displacement of the pipeline is related to the pipe layout
and the pipelines with small vertical stiffness cause abnormal large displacement easily. Several solutions are put forward to solve this problem
such as optimizing and improving the pipe layout
purchasing the pipe with small wall thickness deviation and selecting the constant force hangers with small constant degree and good quality. The research provides reference for solving the same problems.