JING Xuehui, TANG Quanli, ZHU Jianping, et al. Effect of mixing ratio of flue gas in primary air on NOx generation characteristics in Π-type tangentially fired boiler at low load[J]. Thermal power generation, 2020, 49(12): 84-88.
DOI:
JING Xuehui, TANG Quanli, ZHU Jianping, et al. Effect of mixing ratio of flue gas in primary air on NOx generation characteristics in Π-type tangentially fired boiler at low load[J]. Thermal power generation, 2020, 49(12): 84-88. DOI: 10.19666/j.rlfd.202006096.
Effect of mixing ratio of flue gas in primary air on NOx generation characteristics in Π-type tangentially fired boiler at low load
To ensure the powder carrying capacity of primary air
when the boiler is running at a low load
the primary air volume cannot be reduced in proportion to the load
which leads to an increase in oxygen-to-coal ratio at initial stage of combustion and an increase in NO_x production. By using the method of primary air mixed with flue gas
the air volume and oxygen quantity are decoupled
the primary air volume and oxygen quantity are controlled individually
thus to reduce the oxygen concentration on the premise of ensuring the primary air volume
which can decrease the formation of NO_x from the source. According to the structural parameters and low-load operating parameters of a 330 MW unit boiler
numerical simulation was carried out to study the effects of flue gas mixing ratio on the average temperature in furnace section and the volume fraction of O_2 and CO as well as the mass concentration of NO_x produced. The results show that
blending flue gas in primary air at low load can effectively reduce the NO_x generation in the boiler. With the increase of the mixing ratio of flue gas
the average temperature in the furnace section and the CO volume fraction gradually decreases
the average temperature at the furnace outlet gradually increases
and the NO_x production reduces. Compared with the furnace with no flue gas mixing in primary air
the mass concentration of NO_x production in the furnace with flue gas's mixing ratio of 15% reduces by 79.92 mg/m~3.