TONG Jialin, QI Xiaojuan, HAN Ping, et al. Influence of boiler bottom air leakage on performance of a 600 MW unit boiler[J]. Thermal power generation, 2021, 50(4): 126-131.
DOI:
TONG Jialin, QI Xiaojuan, HAN Ping, et al. Influence of boiler bottom air leakage on performance of a 600 MW unit boiler[J]. Thermal power generation, 2021, 50(4): 126-131. DOI: 10.19666/j.rlfd.202006024.
Influence of boiler bottom air leakage on performance of a 600 MW unit boiler
numerical simulation is carried out to study the influence of boiler bottom air leakage on temperature field
burn-out rate
NOx production at typical loads. The results indicate that
after the cold air leaks from dry-type slag extractorthe overall temperature level in the furnace decreases
which has a great effect on combustion stability of the middle and lower burner layers
and the flue gas temperature at the center section of the bottom burner can be reduced by 100 K at low load. Meanwhile
the coal incomplete combustion loss and NO_x production also rises. The influence of air leakage can not be ignored especially when the system is poorly sealed. The exhaust gas temperature rises markedly because X ratio of the air preheater decreases after the boiler bottom air leakage happens.