WANG Pengcheng, CAI Jin, WANG Ke, et al. Influence of coal variation on operation performance of supercritical 350MW CFB boiler[J]. Thermal power generation, 2021, 50(3): 145-151.
DOI:
WANG Pengcheng, CAI Jin, WANG Ke, et al. Influence of coal variation on operation performance of supercritical 350MW CFB boiler[J]. Thermal power generation, 2021, 50(3): 145-151. DOI: 10.19666/j.rlfd.202004139.
Influence of coal variation on operation performance of supercritical 350MW CFB boiler
Based on the variability of coal types used in thermal power plants
the unit parameters before and after changing coal blending scheme in Hepo supercritical 350MW circulating fluidized bed boiler were compared. The influence of coal variation on the boiler operation was analyzed from several aspects
such as air chamber pressure
furnace differential pressure
bed temperature
heating surface parameters
mass ratio of fly ash to bottom slag
NO_x emissions
and coal ash formation characteristics. The results show that
after blending with anthracite from Huanghou mine
the bed temperature increased by an average of 17~27 ℃ and the amount of desuperheating water increased. Besides
the furnace differential pressure decreased by nearly 30% on average and the amount of circulating ash also reduced. Moreover
the discharge slag and the carbon content of fly ash and bottom slag increased
but the NO_x generation amount reduced. The anthracite has low ash content
large calorific value
low attrition rate and poor ash formation characteristics
which will cause changes in material balance characteristics and heat transfer characteristics. Therefore
it is recommended to keep relatively high bed pressure to maintain the load capacity and control the fed-coal particle size to be finer
that is
to increase the mass proportion of particles with size of 500~3200μm and reduce the mass proportion of the maximum particle size range
thus to extend the selection of coal types for circulating fluidized bed boilers and reduce the fuel costs.