LIN Lin, LIU Feng, WANG Hongwu, et al. Low-load operation characteristic analysis and comprehensive optimization of condensate system of a 1000MW unit[J]. Thermal power generation, 2021, 50(3): 152-157.
DOI:
LIN Lin, LIU Feng, WANG Hongwu, et al. Low-load operation characteristic analysis and comprehensive optimization of condensate system of a 1000MW unit[J]. Thermal power generation, 2021, 50(3): 152-157. DOI: 10.19666/j.rlfd.202004101.
Low-load operation characteristic analysis and comprehensive optimization of condensate system of a 1000MW unit
摘要
本文以某超超临界1000MW机组为例
分析了该机组凝结水系统能耗偏高的主要原因
提出了凝结水系统综合优化改造方法
减小了机组凝结水系统阻力
降低了凝结水泵的运行压力。以定性分析结合定量试验的方法
研究了中低负荷段凝结水系统的运行特性
并采用试验的方法进行了优化
探索了凝结水泵最低运行频率。各低负荷工况优化结果表明:在600MW工况下
凝结水系统功耗下降了78.5kW;在500MW工况下
凝结水系统功耗下降了139.6kW;在400MW工况下
凝结水系统功耗下降了187.5kW
折合机组年均厂用电率下降了0.03百分点。
Abstract
By taking an ultra-supercritical 1000MW unit as the object
the main reason for high energy consumption of the condensate system of the unit was analyzed
and the comprehensive optimization retrofit method of the condensate system was put forward
which reduced the resistance of the condensate system and the operating pressure of the condensate pump. The operation characteristics of the condensate system in the middle and low load section were studied by the method of qualitative analysis and quantitative test
and optimized by the experimental method
and the lowest operating frequency of the condensate pump was explored. The optimization results of each low load condition showed that
the power consumption of the condensate system reduced by 78.5 kW at 600MW
and by 139.6 kW at 500 MW. At 400 MW
the power consumption of the condensate system reduced by 187.5 kW
the converted average annual power consumption rate reduced by 0.03 percentage points.