WANG Zhucheng, QUAN Li, ZHANG Guohua, et al. Experimental study on performance of supercritical 350 MW CFB unit based on ASME PTC4 standard[J]. Thermal power generation, 2020, 49(5): 97-103.
DOI:
WANG Zhucheng, QUAN Li, ZHANG Guohua, et al. Experimental study on performance of supercritical 350 MW CFB unit based on ASME PTC4 standard[J]. Thermal power generation, 2020, 49(5): 97-103. DOI: 10.19666/j.rlfd.202002033.
Experimental study on performance of supercritical 350 MW CFB unit based on ASME PTC4 standard
researches on field test of circulating fluidized bed(CFB) units mainly focuse on the optimization adjustment and coal blending
few scholars use ASME PTC4 standard to carry out the study. In this paper
ASME PTC4-2008 standard is applied to analyze the performance test of a supercritical 350 MW CFB unit in a domestic coal-fired power plant
which mainly involves the boiler system boundary
boiler efficiency
dry desulfurization rate
calcium sulfur mole ratio
mass flow of desulfurizer and fuel. When calculating the standard coal consumption rate of power supply
two calculation methods
namely regarding the residual heat income of slag cooler as the effective heat output of boiler or as a heat loss of the boiler
are compared in detail for their influences on the boiler efficiency and the heat consumption rate of steam turbine as well as the standard coal consumption rate of power supply
so as to prevent repeated calculation and missing calculation for heat absorption of slag cooler
and the test case is illustrated. The results show that
the two treatment methods have great influence on boiler efficiency and steam turbine heat rate
the relative deviation is 0.94% and 0.99% respectively
but the standard coal rate of power supply is basically the same
the relative deviation is only 0.05%. The research can provide a reference for performance test of the same type of units.