ZHANG Xiangyu, LU Xu, ZHANG Bo, et al. Experimental study on air staging method in cyclone combustion of Zhundong Coal[J]. Thermal power generation, 2020, 49(9): 150-155.
DOI:
ZHANG Xiangyu, LU Xu, ZHANG Bo, et al. Experimental study on air staging method in cyclone combustion of Zhundong Coal[J]. Thermal power generation, 2020, 49(9): 150-155. DOI: 10.19666/j.rlfd.201912285.
Experimental study on air staging method in cyclone combustion of Zhundong Coal
In order to reduce the NOx emission of cyclone combustion
suitable air staging method on the premise of ensuring stable liquid slagging should be researched. Combined with the viscous-temperature characteristics of Zhundong coal
the liquid slagging model for cyclone furnace was established in this paper
and the excess air coefficient in main combustion zone was determined. Moreover
the air staging combustion test was carried out on a cyclone furnace. The results show that
when the Zhundong coal with good rheology was burned in cyclone furnace
the excess air coefficient in the main combustion zone can be reduced to 0.8. The tangential secondary air was divided into three layers
and the ratio was larger in the upper part and smaller in the lower part
which was 20%
10% and 10% respectively. The over fire air ratio was 30%~35%
and the residence time from the main combustion zone to the over fire air spout should be longer than 0.62 s. When the air supply was deeply staged in the cyclone combustion
the NOx emission mass concentration can be reduced by more than 30%
while the boiler thermal efficiency decreased by 0.22%
which was mainly caused by the increase of unburned carbon content in the slag.