LI Nan, ZHANG Zhixiang, WEI Meng, et al. Antifreeze technology of air heater in combined system of low pressure economizer and air heater[J]. Thermal power generation, 2020, 49(9): 138-143.
DOI:
LI Nan, ZHANG Zhixiang, WEI Meng, et al. Antifreeze technology of air heater in combined system of low pressure economizer and air heater[J]. Thermal power generation, 2020, 49(9): 138-143. DOI: 10.19666/j.rlfd.201912207.
Antifreeze technology of air heater in combined system of low pressure economizer and air heater
摘要
针对低温省煤器与暖风器联合系统中
暖风器在环境温度较低、机组低负荷运行时
易出现换热管冻裂、暖风器系统无法投运的问题
分析了暖风器换热管冻裂的原因
并从结构和系统2方面提出了加厚暖风器换热管弯头
提高换热管内设计工质流速
增设快速放水系统
增设压缩空气吹扫装置以及顺流、逆流切换运行等暖风器防冻改进措施
对于已投运的低温省煤器与暖风器联合系统可通过运行控制降低暖风器冻裂风险。同时
以某600 MW机组二次风暖风器防冻改造为例
在分析暖风器换热管冻裂原因及改进方法的基础上
考虑不同机组所处地区环境温度差异以及防冻要求的不同
提出暖风器防冻设计原则
可为低温省煤器与暖风器联合系统改造提供参考。
Abstract
In the combined system of low pressure economizer and air heater
when the ambient temperature is low and the unit is running at low load
it is prone to the problem that the heat exchanger tube is cracked and the heater system can't be put into operation. The cause of the cracking of the heat exchanger tube in the air heater was analyzed
and the improvement measures for antifreeze of the air heater were proposed from the aspects of structure and system
such as thickening the heat transfer pipe elbow of the air heat
increasing the design working medium speed in the heat transfer tube
adding quick drainage system and compressed air purge device
switching operation along the flow/counterflow direction
and so on. The combined system of low pressure economizer and air heater that had been put into operation could reduce the risk of frost cracking of the air heater through operation control. Taking the antifreeze retrofitting of secondary air heater in a 600 MW as the example
on the basis of analyzing the cause and improvement methods of the cracking of heat exchanger tube in the air heater
considering the difference in ambient temperature between different units and the antifreeze requirements
the design principles of antifreeze for the air heater were proposed
which can provide reference for transformation of combined system of low temperature economizer and air heater.