On-line cation conductivity measurement technology for continuous electroregeneration cation exchanger
The principle and existing problems on-line cation conductivity measurement technology were introduced. The influence factors that existed in the measurement process
such as cation exchange resin regeneration degree
resin crack
resin leakage
exchange column design
sample flow direction in exchange column
air leakage and the rinsing of regenerated resin were analyzed in detail. Moreover
a new technology of on-line cation conductivity measurement using continuous electro-regeneration cation exchanger and its technical superiority were introduced. Moreover
combined with the application of the new technology in power plant
the application prospect of on-line cation conductivity measurement technology was prospected. This technology is of important guiding significance for power plants to obtain accurate cation conductivity and improve reliability of water stream chemical control and supervision.