TENG Da, AN Liansuo, LI Ang, et al. Performance analysis on waste heat and moisture recovery from flue gas by membrane semi-open absorption heat pump[J]. Thermal power generation, 2020, 49(2): 30-37.
DOI:
TENG Da, AN Liansuo, LI Ang, et al. Performance analysis on waste heat and moisture recovery from flue gas by membrane semi-open absorption heat pump[J]. Thermal power generation, 2020, 49(2): 30-37. DOI: 10.19666/j.rlfd.201907133.
Performance analysis on waste heat and moisture recovery from flue gas by membrane semi-open absorption heat pump
The direct discharge of flue gas from the tail of coal-fired utility boilers will cause a lot of waste heat and water loss. Based on the selective permeability of ceramic membrane tubes and the hygroscopicity of lithium bromide solution
a membrane semi-open absorption heat pump system is proposed in this paper
in which multi-channel ceramic membrane tube absorbers absorb waste heat and moisture from flue gas
and high temperature generators
regenerators and gas-liquid separators realize the regeneration of lithium bromide solution. Taking a 330 MW coalfired utility boiler as an example
the effects of circulating fluid parameter
regenerative steam flow and heat exchange amount change inside the absorber on the dewatering performance and heat recovery of membrane semi-open absorption heat pump system are analyzed. The results show that
the flow rate of lithium bromide solution is positively correlated with the outlet temperature and dehydration amount of the solution. The increase of the heat absorbed by condensate water in the absorber increases the dehydration amount
but decreases the outlet temperature of the solution. The change of flow rate of the regenerative steam will change the heat distribution of each part of the system
and the increase of flow rate of the regenerative steam can reduce the heat of driving heat source and improve the heat recovery performance of the system