Mechanism research on linear deviation of low temperature reheater inlet piping
the inlet piping of low temperature reheater of a newly-built 300 MW thermal power unit deviates widely
and the support-hangers are seriously crushed and overloaded. In order to explore the mechanism of pipeline linear deviation
load test of the installed constant support-hangers was carried out
it showed that large load deviation and constant degree exist in the support-hangers. The static simulation calculation of the pipeline indicated that the cold vertical displacement after the trial operation is basically consistent with the measured value
the primary stress of the pipeline in this state exceeds the allowable value
and the thrust and push torque of the end point increase sharply. The analysis shows that
there are many factors leading to the pipeline deviation of power piping
among which the mismatch between the support-hanger loads and the piping weight is the most critical one
which is caused by the large constant degree and load deviation of the constant hanger. The structural characteristics of the constant support-hanger determine that it can not maintain constant output load between the cold and hot state. It is suggested that in the design of the power piping
the arrangement of support-hangers on the pipeline should be optimized as far as possible
and the purchase and daily maintenance of support-hangers should be strengthened in the management and supervision.