WANG Lin, WANG Hongyu, GAO Jinghui, et al. Study on blowing process of oxide skin of steam pipeline in a 1000 MW unit[J]. Thermal power generation, 2020, 49(2): 93-98.
DOI:
WANG Lin, WANG Hongyu, GAO Jinghui, et al. Study on blowing process of oxide skin of steam pipeline in a 1000 MW unit[J]. Thermal power generation, 2020, 49(2): 93-98. DOI: 10.19666/j.rlfd.201905087.
Study on blowing process of oxide skin of steam pipeline in a 1000 MW unit
摘要
为分析超超临界1 000 MW机组锅炉高温过热器管泄漏原因
对现场采集的管样进行了宏观形貌检查、理化性能试验、显微组织分析及材料硬度测试。结果表明
锅炉高温过热器管泄漏原因为管道内氧化皮剥落
堵塞管道
引起局部过热所致。对此
提出利用高低压旁路
进行常态化蒸汽吹扫
以实现锅炉蒸汽管道内氧化皮受控剥落、有序排出
保证机组后期的运行安全。氧化皮常态化吹扫方案实际应用效果良好
可为同类机组提供参考。
Abstract
In order to analyze the causes of leakage of high temperature superheater tubes in an ultra-supercritical 1 000 MW unit boiler
macro-morphology examination
physical and chemical properties test
microstructure analysis and material hardness test were carried out on the samples collected on site. The test results show that
the leak reason is that the oxide scales on the pipeline peel off
leading to blockage of the pipeline and local overheating. Thus
a preventive steam purging method using high and low pressure bypass is proposed to realize controlled peeling and orderly discharge of oxide scales on boiler steam pipes and ensure the safety of the later operation of the unit. The practical application effect of the oxide scale stripping and purging method is good
ANALYSIS OF OVERTEMPERATURE PROBLEM OCCURRED ON PIPE WALL OF HIGH-TEPERATURE HEATING SURFACE FOR BOILERS IN ZHUHAI POWER PLANT AND SOLVING SCHEME THEREOF
INFLUENCE OF OXYGEN TREATMENT FOR SUPERCRITICAL UNITS UPON FORMATION AND PEEL-OFF OF OXIDE SKIN
CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT
Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition
Research on main and reheat steam temperature lifting method for ultra supercritical 1000 MW unit double-tangential circular boiler
Related Author
YE Shan-pei1
WANG Chun-chuang21.Guangqian Electric Power Co Ltd
YU Xuebin
HE Guilin
WANG Hai'ou
GENG Zhaolong Guohua Panshan Power Generation Co Ltd
ZHAO Mingzhong
WU Kai Gansu Electric Power Science Research Institute
Related Institution
Guangqian Electric Power Co., Ltd
Guohua Panshan Power Generation Co., Ltd
Gansu Electric Power Research Institute
College of Architecture and Surveying Engineering, Datong University