Leakage detection device of condenser heat exchanger tubes: application situation and improvement measures
Focusing on the current application status of condenser leak detection devices in power plants with high equipped rate
low operating rate and poor reliability
the main reasons for the lack of water samples
small detection range and long detection time of existing leak detection devices are found out
through the investigation and analysis of condenser leak forms and design schemes of existing condenser leak detection devices. Moreover
the measures for improving the reliability of condenser leak detection devices are given. According to the specific structure of the condenser and the distribution of condensate flow field
the improved leak detection device has a specific design sampling point. Each water chamber is sampled independently and measured independently. It is equipped with an intelligent leak state diagnosis system
which can give important information such as leak area
leakage volume
leakage rate and equivalent diameter of leak hole in real time
and provide reliable basis for subsequent leak detection and plugging and decision-making
and also solve the shortcomings of the existing condenser leak detection devices.