LI Jiahu, WANG Xiaotao, ZHANG Meng, et al. A noval acid dew point calculation formula and its field experiment verification[J]. Thermal power generation, 2019, 48(4): 110-115.
DOI:
LI Jiahu, WANG Xiaotao, ZHANG Meng, et al. A noval acid dew point calculation formula and its field experiment verification[J]. Thermal power generation, 2019, 48(4): 110-115. DOI: 10.19666/j.rlfd.201808188.
A noval acid dew point calculation formula and its field experiment verification
The acid dew point of flue gas is an important factor that restricts deep waste heat recovery technology.Accurate prediction of this value is of great significance for avoiding low temperature corrosion
reducing heat loss of flue gas and improving boiler efficiency. Based on the analysis and comparison of common calculation formulas of acid dew point
the least square method is used to fit the relevant experimental data to obtain the fitted formula
which is analyzed through theoretical calculation and field measurement data of relevant scholars in recent years. The calculation results of the formula proposed in this paper are verified by using self-designed measurement device of acid dew point. The result shows that the formula proposed in this paper not only has a more reasonable range of numerical prediction
but also has higher accuracy than others when the volume fraction of SO3 is below 20 mL/m3.