CHEN Xuwei, HE Lijun, CHEN Guoqing, et al. Distribution characteristics of reductive atmosphere close to water wall of an ultra supercritical 1000MW boiler with dual tangential circle[J]. Thermal power generation, 2018, 47(11): 115-122.
DOI:
CHEN Xuwei, HE Lijun, CHEN Guoqing, et al. Distribution characteristics of reductive atmosphere close to water wall of an ultra supercritical 1000MW boiler with dual tangential circle[J]. Thermal power generation, 2018, 47(11): 115-122. DOI: 10.19666/j.rlfd.201804075.
Distribution characteristics of reductive atmosphere close to water wall of an ultra supercritical 1000MW boiler with dual tangential circle
Taking an ultra supercritical 1 000 MW boiler with dual tangential circle as the research object
the flue gas components(O_2
CO and H_2S) near the water wall were detected under different operational conditions. Moreover
the influences of several factors
such as the second-air distribution mode
the separated over-fired air(SOFA) flow rate
the circumferential air flow rate and the second-air flow rate distribution at the same layer burners
on the volume fraction of O_2
CO and H_2S close to the water wall were analyzed. The results show that
affected by the special aerodynamic field inside the furnace
the areas close to burners 2
3
5 and 8 have the relative stronger reductive atmosphere and higher temperature. Regulating the secondary air distribution and SOFA flow rate
as well as increasing air flow rate of the primary combustion zone and reducing zone
could weaken the reductive atmosphere near the water wall. The reductive atmosphere near the hot corner water wall could be decreased by adjusting the circumferential air flow rate and second-air flow rate distribution at the same layer burner
and increasing the second air jet momentum of burners 1