WANG Xingguo, JIANG Kuizhen, HAN Zhonghe, et al. Thermoelectric relationship of a heat supply unit equipped with Li Br absorption heat pump[J]. Thermal power generation, 2018, 47(8): 79-84.
DOI:
WANG Xingguo, JIANG Kuizhen, HAN Zhonghe, et al. Thermoelectric relationship of a heat supply unit equipped with Li Br absorption heat pump[J]. Thermal power generation, 2018, 47(8): 79-84. DOI: 10.19666/j.rlfd.201803076.
Thermoelectric relationship of a heat supply unit equipped with Li Br absorption heat pump
摘要
为消纳风电
供热机组在承担供热任务要求的同时需要尽可能参与电网调峰。供热机组配置溴化锂吸收式热泵
在回收循环水余热的同时扩大了机组的供热能力
其热电关系需要进一步分析确定。本文建立了国产某300 MW供热机组模型
分析其加装热泵前后热电关系的变化。结果表明:在配置2台单机容量为46.6 MW溴化锂吸收式热泵后
供热负荷增加了39 MW
同时在给定热负荷下电负荷可变范围最大可扩大9%;实际运行中
循环水温度变化对机组最小发电量影响较大
而热网回水温度对机组热电关系几乎无影响。
Abstract
In order to solve the problem of wind power accommodation
the heat supply units need to participate in peak regulation of the power grid as much as possible while undertaking the requirements for heating task. The heat supply unit is equipped with a Li Br absorption heat pump
which can recover the residual heat of the circulating water and increase the heat capacity of the unit. The thermoelectric relationship needs to be further analyzed and determined. A domestic model of a 300 MW heating unit is established to analyze the change in the thermoelectric relationship before and after the installation of the heat pump. The results show that
after the installation of two 46.6 MW Li Br absorption heat pumps
the heating load increases by 39 MW. At the same time
the maximum variable load range of the electric load at a given heat load can be increased by 9%. In actual operation
the change of circulating water temperature has a great influence on the minimum generating capacity of the unit
while the return water temperature of the heating network has little effect on the unit's thermoelectric relationship.