DONG Xuelian, LUO Hao, ZHOU Rong, et al. Analysis on flow field characteristics of a new type of labyrinth control valve[J]. Thermal power generation, 2018, 47(10): 66-72.
DOI:
DONG Xuelian, LUO Hao, ZHOU Rong, et al. Analysis on flow field characteristics of a new type of labyrinth control valve[J]. Thermal power generation, 2018, 47(10): 66-72. DOI: 10.19666/j.rlfd.201801002.
Analysis on flow field characteristics of a new type of labyrinth control valve
The labyrinth control valve is one of the important components of the feedwater bypass system of oncethrough boiler in the supercritical(ultra-supercritical) unit. The type and structural parameters of the labyrinth runner are the key to designing the labyrinth control valves
which directly affect the flow field distribution in the valve. On the basis of flow characteristics of the conventional divided-flow and hedge-type runner
a new disc structure is proposed in this paper. In addition
through numerical simulation by the CFX software
the flow field distribution characteristics of the valve with new disc structure and different structural parameters are studied. The results show that
the new disc structure has good flow characteristics
flow resistance characteristics and flow capacity
which can meet the requirements of the valve. In the disc structure parameters
with the increase of the runner depth
the average outlet pressure decreases
and the flow rate and the average outlet velocity increase. With the increase of the runner chamfer
the flow rate and the average outlet velocity increases
while the average outlet pressure decreases and the cavitation occurs in some areas. Furthermore
with the increase of the width of the hedgetype runner and the width of inlet runners and outlet runners
the flow rate increases
and the average outlet pressure and speed show a downward trend. The depth and the chamfer of the runner have a great influence on the flow field
while the effect of the width of the hedge-type runner
the width of the inlet runners
and the width of the outlet runners on the flow field of the valve is limit.
Simulation modelling of power system for supercritical units considering dynamic heat exchange of once-through boiler
PRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS
ENERGY-SAVING IN PLANT SERVICE POWER CONSUMPTION OF IMPORTED 360 MW UNITS AND BENEFIT ANALYSIS THEREOF
MATHEMATIC MODEL AND DYNAMIC CHARACTERISTICS OF ONCE-THROUGH BOILER FOR A 300 MW UNIT
EXPLORATION OF FEED-WATER AVT(O) TREATMENT FOR ONCE-THROUGH BOILER OF SUPERCRITICAL 600 MW UNIT
Related Author
XU Fei
HUANG Yihan
LI Jiangpeng
LIU Yifeng
QI Xin
CHEN Lei
HAO Ling
XU Darui
Related Institution
State Grid Ningxia Electric Power Co., Ltd
National Key Laboratory of New Power System Operation and Control, Tsinghua University
Department of Electrical Engineering and Applied Electronic Technology, Tsinghua University
Guangdong Electric Honghai Bay Power Generation Co., Ltd.