LI Haoyu, ZHU Xianran, LIU Yanpeng, et al. Technical research on in-deep mixedly burning inferior coal in a 600 MW unit boiler[J]. Thermal power generation, 2018, 47(7): 99-104.
DOI:
LI Haoyu, ZHU Xianran, LIU Yanpeng, et al. Technical research on in-deep mixedly burning inferior coal in a 600 MW unit boiler[J]. Thermal power generation, 2018, 47(7): 99-104. DOI: 10.19666/j.rlfd.201710097.
Technical research on in-deep mixedly burning inferior coal in a 600 MW unit boiler
According to the actual situation and safety and environmental requirement of the boiler
a method for determining the scheme of in-deep mixedly burning inferior coal is proposed through applying mathematical model. Taking a 600 MW unit boiler as an example
the scheme of in-deep mixedly burning inferior coal at full load is made and the field verification experiment of mixedly burning is carried out. The results show that
the proposed scheme in this study can maximize the profit of the mixedly burning inferior coal with the precondition of safety and environmental operation of boiler. The maximum mixing ratio of inferior coal is 30% in the test unit at full load. Furthermore
with the increase of the mixing ratio of inferior coal
the efficiency of boiler decreases and the auxiliary power consumption rate increases. However
considering the coal cost