Parameter optimization for combined system of low pressure economizer and air heater
The research status of the combined system of low pressure economizer and air heater was introduced. By taking a 660 MW unit in Shandong Province as the example
the influence of heat exchange area of low pressure economizer and outlet air temperature of air heater on energy conservation potential
static investment and static payback period of the whole system was calculated. The result shows that
the larger the heat exchange area of low pressure economizer
the greater the energy conservation potential and static investment. The static payback period of the system decreases at first and then increases with the increaing heat exchange area of the low pressure economizer. The higher the air temperature at the air heater outlet
the greater the energy conservation potential and static investment. The static payback period of the system decreases at first and then increases with the increasing air temperature at the air heater outlet. It is recommended that the low pressure economizer be arranged with 40 rows in vertical direction
and the air temperature at the air heater outlet be 65~75 ℃.