Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation
|更新时间:2025-09-28
|
Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation
Thermal Power GenerationVol. 47, Issue 3, Pages: 128-134(2018)
DONG Ruifeng, WU Wenlong, WANG Fengtao, et al. Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation[J]. Thermal power generation, 2018, 47(3): 128-134.
DOI:
DONG Ruifeng, WU Wenlong, WANG Fengtao, et al. Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation[J]. Thermal power generation, 2018, 47(3): 128-134. DOI: 10.19666/j.rlfd.201706048.
Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation
the contaminants emission limits of coal-fired power plants are reduced hugely and the statuses of emission reduction equipment are getting worse simultaneously. Hence
new operation problems have appeared in the flue gas purification equipment. Crystallization problem has taken place in the flue system of some coal-fired power plants
such as on the surface of bag filter clean room
induced draft fan hub
FGD inlet flue and so on. The results of the crystal analysis show that the main component of crystalline is ammonium chloride
which is up to 90%. In this study
the crystallization reaction mechanism of ammonium chloride was studied and calculated. The results show that the crystallization temperature of ammonium chloride is about 75-115 °C. Therefore
the crystallization problems of ammonium chloride could be found in the dust separator
induced draft fan and GGH. The crystallization of ammonium chloride could not only clog the equipment
but also corrode the surfaces of the flue system. According to the actual operation situation
some prevention and control measures are proposed. And this paper suggested to reduce the concentrations of ammonia and hydrogen chloride in the flue gas to avoid the crystallization problem of ammonium chloride.