TIAN Ye, DU Ling, WU Yingqing, et al. Influence of pretreatment methods on detection of potassium and sodium in coal[J]. Thermal power generation, 2018, 47(2): 49-55.
DOI:
TIAN Ye, DU Ling, WU Yingqing, et al. Influence of pretreatment methods on detection of potassium and sodium in coal[J]. Thermal power generation, 2018, 47(2): 49-55. DOI: 10.19666/j.rlfd.201704019.
Influence of pretreatment methods on detection of potassium and sodium in coal
摘要
针对目前煤中钾、钠测定方法少、准确度低等问题
采用国标法、酸溶法和微波消解法对多种低阶煤中钾、钠含量进行测定
并对微波消解法进行精密度测试。结果表明:测定煤中钾、钠含量时
国标法中钾、钠均有损失;酸溶法中钠损失较小
钾在煤中钾、钠含量都高时
损失较大
反之较小;微波消解法准确度好、精密度高
符合煤中钾、钠的测定要求。
Abstract
Currently
there are few methods to determine the potassium and sodium contents in coal
and the methods are usually of low accuracy. To solve this problem
the national standard method
acid soluble-AAS method and microwave digestion-AAS method were used to detect the potassium and sodium contents in various kinds of low-valence coals
and the precision of the microwave digestion-AAS method was tested. The results show that
by adopting the national standard method
there was a loss of potassium and sodium. While by employing the acid soluble-AAS method
the loss of sodium was comparatively low
that of potassium was relatively high when the potassium and sodium contents in the coal were both high(otherwise it would be low). The microwave digestion-AAS method had high accuracy and precision