Thermal fatigue failure analysis for drainage-tank in hot section of reheat pipeline in an ultra supercritical 1 000 MW unit
更新时间:2025-09-28
    • Thermal fatigue failure analysis for drainage-tank in hot section of reheat pipeline in an ultra supercritical 1 000 MW unit

    • Thermal Power Generation   Vol. 47, Issue 1, Pages: 130-135(2018)
    • DOI:10.19666/j.rlfd.201704016    

      CLC: TM621
    • Published:2018

    移动端阅览

  • LOU Yumin, PENG Yichao, TU Rongfeng, et al. Thermal fatigue failure analysis for drainage-tank in hot section of reheat pipeline in an ultra supercritical 1 000 MW unit[J]. Thermal power generation, 2018, 47(1): 130-135. DOI: 10.19666/j.rlfd.201704016.

  •  
  •  

0

Views

111

下载量

1

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

ANALYSIS OF TYPICAL METALLIC PARTS FAILURES OCCURRED ON UTILITY BOILERS AND PREVENTIVE MEASURES THEREOF
Reason analysis on leakage of T92 steel tube in an ultra supercritical boiler and the countermeasures
Typical faults and countermeasures of flue gas cooler for coal-fired boilers
RETROFITTING OF AUXILIARY VALVE FOR SOLENOID BLOWOUT VALVES
ANALYSIS OF SUPERHEATER'S TUBE-BURST CAUSED BY FALLING-AWAY OF OXIDE SKIN

Related Author

LONG Huiguo
CHEN Hongdong
LONG YiHunan Provincial Electric Power Testing and Research Institute
LI Shunhua
HU Ping
MA Qingzeng Electric Power Research Institute of Guangdong Power Grid Corporation
HU Fangfang
REN Jiyun

Related Institution

Hunan Electric Power Company Experimental Research Institute
Guangdong Power Grid Corporation Electric Power Science Research Institute
School of Foreign Languages, Xi'an Jiaotong University
State Key Laboratory of Multiphase Flow for Power Engineering, Xi'an Jiaotong University
China Energy Engineering Group Shaanxi Electric Power Design Institute Co., Ltd