STUDY ON SELECTING DEEP DESULPHURIZATION MODE FOR 1025 t/h CFB BOILER
The status quo of CFB boiler+tail section flue gas desulphurization technology at abroad
as well as the principle of selecting tail section desulphurization mode
have been presented.Through analysis and comparison of several main desulphurization modes
such as wet limestone/gypsum method
flue gas CFB dry method
rotary spray semi-dry method
calcium-spraying into furnace-tail section humidifying activation method
and single calcium-spraying into furnace method etc.
it is believed that the first-stage desulphurization in the furnace of CFB boiler + secondary-stage desulphurization in the tail section with humidifying activation is the reasonable mode for deep desulphurization of large-capacity CFB boiler