ZHANG Guang-wen Beijing Guohua Electric Power Technique Research Center Co.. TEST STUDY ON THE CALCULATION METHOD OF ENRICHMENT FACTOR FOR CIRCULATORY COOLING WATER[J]. Thermal power generation, 2008, 37(12): 90-93.
DOI:
ZHANG Guang-wen Beijing Guohua Electric Power Technique Research Center Co.. TEST STUDY ON THE CALCULATION METHOD OF ENRICHMENT FACTOR FOR CIRCULATORY COOLING WATER[J]. Thermal power generation, 2008, 37(12): 90-93. DOI: 10.19666/j.rlfd.2008.12.023.
TEST STUDY ON THE CALCULATION METHOD OF ENRICHMENT FACTOR FOR CIRCULATORY COOLING WATER
摘要
对目前火电厂循环冷却水采用的浓缩倍率计算方法进行总结
通过对不同水体的实验室试验
提出补充水水质为不稳定的单一水源及多种水源时循环冷却水浓缩倍率的计算方法
并给出了不同计算方法的适用范围。
Abstract
The calculation methods of enrichment factor used at present for circulatory cooling water in thermal power plants have been summarized
and the calculation method of enrichment factor for make-up water and circulatory cooling water with one or several water sources being put forward.Through test study for different water bodies in the laboratory
the applicable range of different calculation methods has been given.
DEVELOPMENT OF RECIRCULATING COOLING WATER TREATMENT TECHNIQUES IN THERMAL POWER PLANTS OF OUR COUNTRY
APPLICATION OF WASTE WATER INTO CIRCULATING WATER SYSTEM OF A THERMAL POWER PLANT
INFLUENCE OF NITRIFICATION PROCCESS CONCERNING AMMONIUM NITROGEN UPON THE OPEN TY-PE CIRCULATING COOLING WATER SYSTEM IN THERMAL POWER PLANTS
ANTI-CORROSION AND SCALE-RETARDATION TECHNIQUE AT THE TIME OF HIGH ENRICHMENT RATE FOR REUSING SECONDARY URBAN SEWAGE AS CIRCULATORY COOLING WATER IN THERMAL POWER PLANT
RETROFIT OF 600 m3/h MECHANICALLY AGITATED SETTLING POND IN BAOJI POWER PLANT NO. 2