CAUSE ANALYSIS ABOUT FRACTURE OF SEALING WELD JOINTS ON CEILING OF BOILER'S REHEATER AND STRUCTURE RETROFIT THEREOF
The cause resulting in weld joint fracture on comb-shaped sealing structure of wall-penetrating pipe on the ceiling of reheater for 2008 t/h boiler have been analyzed
it is believed that the main causes leading to weld joint fracture are improper structure of the ceiling's sealing plate
and poor weld quality of the said plate
etc..For these
structural retrofit
such as additionally installing casing pipe in the transition section on sealing plate
and outside the rear-platen reheater and final-stage reheater
and measures for enhancing weld quality
etc.
have been put forward.After implementation
fracture has not occurred again at these locations.