LI Zhi-hua Guohua Panshan Power Generation Co Ltd. CAUSE ANALYSIS OF SECONDARY CLOSING FAULTY FOR CIRCULATING-WATER PUMP OF UNIT NO.1 AND SOLVING MEASURES THEREOF[J]. Thermal power generation, 2008, (10): 77-79.
DOI:
LI Zhi-hua Guohua Panshan Power Generation Co Ltd. CAUSE ANALYSIS OF SECONDARY CLOSING FAULTY FOR CIRCULATING-WATER PUMP OF UNIT NO.1 AND SOLVING MEASURES THEREOF[J]. Thermal power generation, 2008, (10): 77-79. DOI: 10.19666/j.rlfd.2008.10.022.
CAUSE ANALYSIS OF SECONDARY CLOSING FAULTY FOR CIRCULATING-WATER PUMP OF UNIT NO.1 AND SOLVING MEASURES THEREOF
摘要
国华盘山发电有限责任公司(简称盘电)1号机组在小修调试时
由于动力开关合闸不到位
造成二次合闸。对此
从逻辑设计方面对二次合闸的原因进行了分析
并提出了解决方法。该经验可对电厂泵、风机等设备的故障原因分析提供帮助。
Abstract
In debugging process after temporary repair of unit no.1 in Guohua Panshan Power Generation Co Ltd
the secondary closing faulty had occurred due to the power switch being not closed to the right position.For this
the cause resulting in secondary closing faulty has been analysed from logic design aspect
and solving method being put forward
providing with help for analysing causes led to equipment troubles for pumps and fans in power plants.