LIU Yan-feng, MENG Jian-chao, HU Ji-wu Datang Huayin Jinzhushan Thermal Power Generation Branch Company. CAUSE ANALYSIS OF COAL-PLUGGING IN BALL MILL WITH DOUBLE INLET AND DOUBLE OUTLET AND RESOLVING MEASURES THEREOF[J]. Thermal power generation, 2008, (10): 55-56.
DOI:
LIU Yan-feng, MENG Jian-chao, HU Ji-wu Datang Huayin Jinzhushan Thermal Power Generation Branch Company. CAUSE ANALYSIS OF COAL-PLUGGING IN BALL MILL WITH DOUBLE INLET AND DOUBLE OUTLET AND RESOLVING MEASURES THEREOF[J]. Thermal power generation, 2008, (10): 55-56. DOI: 10.19666/j.rlfd.2008.10.016.
CAUSE ANALYSIS OF COAL-PLUGGING IN BALL MILL WITH DOUBLE INLET AND DOUBLE OUTLET AND RESOLVING MEASURES THEREOF
摘要
双进双出钢球磨煤机在运行中存在堵煤现象
主要因料位控制系统故障所致。对此
在运行中应对料位控制系统进行检查
消除传压管路堵塞、漏气和测量喷嘴、控制回路等缺陷
保证料位控制系统正常
进而防止磨煤机堵煤。
Abstract
The cause leading to coal plugging phenomenon in operation of ball mill with double inlet and double outlet is due to the faulty occurred in the medium-level controlling system.It is recommented to strengthen inspection and repair of the said system
eliminating blockage and air leakage in pressure-transfering pipeline
as well as defects of measuring nozzle and control circuit
thus to thoroughly eliminate coal-plugging phenomenon in the ball mill.