LIU Bing1, ZHENG Fang-ping2, ZHANG Lei2, et al. ANALYSIS OF TUBE-BURST FAILURE ON WATER-WALL IN BOILERS FOR SUBCRITICAL 300 MW UNIT[J]. Thermal power generation, 2008, (10): 35-38.
DOI:
LIU Bing1, ZHENG Fang-ping2, ZHANG Lei2, et al. ANALYSIS OF TUBE-BURST FAILURE ON WATER-WALL IN BOILERS FOR SUBCRITICAL 300 MW UNIT[J]. Thermal power generation, 2008, (10): 35-38. DOI: 10.19666/j.rlfd.2008.10.010.
ANALYSIS OF TUBE-BURST FAILURE ON WATER-WALL IN BOILERS FOR SUBCRITICAL 300 MW UNIT
the causes leading to burst of rifled tubes on the water-wall in boilers for subcritical 300 MW unit have been tested and analysed.Results of test show that the tube-burst is due to hydrogen damage.