MAO Xiao-fei, LI Jiu-hua, CHEN Nian-zu Jiangxi Provincial Electric Power Science Research Institute. AN APPROACH TO CALCULATION METHOD OF ACTIVATION ENERGY IN COMBUSTION TEST OF BLIND COAL[J]. Thermal power generation, 2008, (10): 23-27.
DOI:
MAO Xiao-fei, LI Jiu-hua, CHEN Nian-zu Jiangxi Provincial Electric Power Science Research Institute. AN APPROACH TO CALCULATION METHOD OF ACTIVATION ENERGY IN COMBUSTION TEST OF BLIND COAL[J]. Thermal power generation, 2008, (10): 23-27. DOI: 10.19666/j.rlfd.2008.10.007.
AN APPROACH TO CALCULATION METHOD OF ACTIVATION ENERGY IN COMBUSTION TEST OF BLIND COAL
By using Freeman-Carroll method (differential method)and Coats-Redfern method(integral method)in the individually scanning rate method
the activation energy in combustion reaction of blind coal in two kinds has been studied.Results show that the heating rate has greater effect on the E value of activation energy
the E value decreases along with the heating rate's increasing.In the event of lower heating rate
the Freeman-Carroll method uses data on DTG curve
while Coats-Redfern method only uses data on TG curve.From view point of relative coefficient R in data fitting
the error factor in test(i.e.the non-smooth part on DTG curve)has more greater effect on the activation energy calculated by Freeman-Carroll method;in case of higher heating rate
the measured DTG curve tends to be smooth
the influence of error factor R in test upon the calculated result by using Freeman-Carroll method decreases.In addition
along with increasing the heating rate
(2RT)/E tends to be increased
so the hypothesis of (2RT)/E1 in Coats-Redfern method isn't fully rational.