HAN Ke-gang Huaneng Yuhuan Power Plant. COMPARATION OF RESULTS FROM BLOWING STEAM-PIPELINES OF ULTRA-SUPERCRITICAL UNIT UNDER PRESSURE-STABILIZING AND PRESSURE-REDUCING CONDITONS[J]. Thermal power generation, 2008, (9): 62-64.
DOI:
HAN Ke-gang Huaneng Yuhuan Power Plant. COMPARATION OF RESULTS FROM BLOWING STEAM-PIPELINES OF ULTRA-SUPERCRITICAL UNIT UNDER PRESSURE-STABILIZING AND PRESSURE-REDUCING CONDITONS[J]. Thermal power generation, 2008, (9): 62-64. DOI: 10.19666/j.rlfd.2008.09.018.
COMPARATION OF RESULTS FROM BLOWING STEAM-PIPELINES OF ULTRA-SUPERCRITICAL UNIT UNDER PRESSURE-STABILIZING AND PRESSURE-REDUCING CONDITONS
Four 1000 MW ultra-supercritical coal-fired units had been installed in Huaneng Yuhuan Power Plant.The pipe-blowing with steam for units no.1 and no.2 in the first-phase project was using different schemes
namely pressure-stabilizing and pressure-reducing respectively.The pipe-blowing with steam for units in the second-phase project draws fully on the experience of pipe-blowing with steam for units in the first-phase project
selecting a scheme of two-stage pipe-blowing under pressure-reducing condition.Comparing with pressure-stabilizing method
the pressure-reducing method not only has good effectiveness