WANG Juan1, LI Wen-bing2, GAO Jian-hong2, et al. CAUSE ANALYSIS AND COUNTERMEASURES FOR COLOR DARKENING OF FIRE-RESISTANT OIL USED FOR UNIT NO.1 IN WUHAI POWER PLANT[J]. Thermal power generation, 2008, (8): 76-78.
DOI:
WANG Juan1, LI Wen-bing2, GAO Jian-hong2, et al. CAUSE ANALYSIS AND COUNTERMEASURES FOR COLOR DARKENING OF FIRE-RESISTANT OIL USED FOR UNIT NO.1 IN WUHAI POWER PLANT[J]. Thermal power generation, 2008, (8): 76-78. DOI: 10.19666/j.rlfd.2008.08.022.
CAUSE ANALYSIS AND COUNTERMEASURES FOR COLOR DARKENING OF FIRE-RESISTANT OIL USED FOR UNIT NO.1 IN WUHAI POWER PLANT
such as analysis of oil quality before and after regeneration
overtemperature deterioration under different temperature
and infrared spectroscopic analysis etc.
has been carried out for fire-resistant oil used for unit no.1 in Wuhai Power Plant.Results show that the cause leading to color darkening of fire-resistant oil in operation is occurrence of local overheated spots
making the oil temperature in operation to be overhigh
resulting in quality deterioration of oil
and producing substances that might darken the oil color.The result of study also shows that the oil quality has been substantially improved after on-line by-pass regeneration by adopting KZT2-2 type regeneration facility for deteriorated fire-resistant oil
making each performance index of oil to be reached the requirements of standard for new oil.