LIU Guang-chen1, YANG De-rong2, ZHANG Ying-xian2 1.Inner-mongolia University of Industry. ENERGY-SAVING RETROFIT OF THE CONDENSATE PUMP FOR 600 MW UNIT BASED ON MEDIUM-VOLTAGE FREQUENCY CONVERSION TECHNOLOGY[J]. Thermal power generation, 2008, (8): 62-64.
DOI:
LIU Guang-chen1, YANG De-rong2, ZHANG Ying-xian2 1.Inner-mongolia University of Industry. ENERGY-SAVING RETROFIT OF THE CONDENSATE PUMP FOR 600 MW UNIT BASED ON MEDIUM-VOLTAGE FREQUENCY CONVERSION TECHNOLOGY[J]. Thermal power generation, 2008, (8): 62-64. DOI: 10.19666/j.rlfd.2008.08.018.
ENERGY-SAVING RETROFIT OF THE CONDENSATE PUMP FOR 600 MW UNIT BASED ON MEDIUM-VOLTAGE FREQUENCY CONVERSION TECHNOLOGY
摘要
介绍了大唐托克托发电有限责任公司2×600 MW机组凝结水泵的中压变频改造设计与运行情况
并对改造后的经济效益进行了分析。运行结果证明
在火电厂辅机中利用中压变频技术进行调节具有良好的技术性能和显著的经济效益。
Abstract
The design and operating condition of medium-voltage frequency conversion retrofit for the condensate pump of 2×600 MW units in Tuoketuo Power Generation Co Ltd have been presented
and the economic benefits after retrofit being analysed.Results of operation show that the medium-voltage frequency conversion technology being applied to auxiliary machines in thermal power plants boasts outstanding technical performance and remarkable economic benefit.