CAUSE ANALYSIS OF TENSION ROD RUPTURE OF MPS COAL PULVERIZER AND COUNTERMEASURES THEREOF
更新时间:2025-09-28
    • CAUSE ANALYSIS OF TENSION ROD RUPTURE OF MPS COAL PULVERIZER AND COUNTERMEASURES THEREOF

    • Thermal Power Generation   Issue 8, Pages: 45-46(2008)
    • DOI:10.19666/j.rlfd.2008.08.012    

      CLC: TK223.25
    • Published:2008

    移动端阅览

  • NING Guo-rui1, LI Zhi-shan2, WANG Qiang1 1.Beijing Guohua Electric Power Technology Research Centre Co Ltd. CAUSE ANALYSIS OF TENSION ROD RUPTURE OF MPS COAL PULVERIZER AND COUNTERMEASURES THEREOF[J]. Thermal power generation, 2008, (8): 45-46. DOI: 10.19666/j.rlfd.2008.08.012.

  •  
  •  

0

Views

89

下载量

2

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

NUMERICAL CALCULATION OF MULTIFACTORS AFFECTING PASSAGE RATE OF PARTICLES IN FLUE GAS ACROSS SMOOTHTUBE BUNDLES OF INLINE ARRANGEMENT
ANALYSIS OF OPERATION PROBLEMS CONCERNING AIR-AND-WATER JOINTLY OPERATED SLAG COOLER OF A 440t/h CFB BOILER AND IMPROVEMENT THEREOF
CAUSE ANALYSIS OF TUBE-BURST IN LOW-TEMPERATURE REHEATER
RETROFIT OF NOZZLE RING FOR MPS-255 MEDIUM SPEED COAL MILL
SIMULATION AND ANALYSIS ABOUT WORN-OUT ON CONNECTING PIPE OF LOW-PRESSURE REHEATER FOR A BOILER OF 600 MW UNIT

Related Author

LU Guodong
ZHOU Qiangtai
QIAN Zhiyong
HU Lin-ming1
LONG Hui-guo2
LI Guang21.Hunan Provincial Electric Power Testing & Research Institute
XIAO Yong-hui
GAO Dian-chenYuanbaoshan Power Generation Co Ltd

Related Institution

Zhejiang University
Southeast University
Jiangxi Electric Power Test and Research Institute
Loudi Special Equipment Inspection Institute
Hunan Electric Power Test and Research Institute
0