JIANG Hao1, LI Yun2, LI Heng3, et al. FILTRATION TREATMENT OF THERMODYNAMIC PARAMETERS CONCERNING THERMAL POWER UNIT BASED ON EMPIRICAL MODE DECOMPOSITION[J]. Thermal power generation, 2008, (6): 64-68.
DOI:
JIANG Hao1, LI Yun2, LI Heng3, et al. FILTRATION TREATMENT OF THERMODYNAMIC PARAMETERS CONCERNING THERMAL POWER UNIT BASED ON EMPIRICAL MODE DECOMPOSITION[J]. Thermal power generation, 2008, (6): 64-68. DOI: 10.19666/j.rlfd.2008.06.018.
FILTRATION TREATMENT OF THERMODYNAMIC PARAMETERS CONCERNING THERMAL POWER UNIT BASED ON EMPIRICAL MODE DECOMPOSITION
The fluctuation of on-line performance monitoring results is very large
this problem must be overcome in the technology of units' performance monitoring and diagnosis.The real signal of units' performance variation resulting from variation of operating parameters and equipment performance is drowned in many noises
leading to correct analysis results being unable to be obtained.For this
the units' thermodynamic parameters have been filtered by using the multiscale filtering character of the empirical mode decomposition.The fluctuation of units' heat consumption rate calculated by using the filtered data has been apparently improved
the fluctuation range being decreased from 2.5% to 0.3%
and the result correctly reflecting the trend of heat consumption rate variation along with the load.