RETROFIT OF AIR CAP FOR A 130t/h CFB BOILER
摘要
石家庄诚峰热电有限公司4号机组130 t/h循环流化床锅炉风帽磨损严重
分析了风帽磨损的原因
并对其进行了相应的技术改造。试验结果表明
改造后的风帽空板阻力降低
布风均匀
流化状态良好;改后年节电约折合11.9万元
节煤约折合8.9万元
节约更换风帽备件费用约4.9万元
经济效益显著。
Abstract
The air cap of a 130 t/h circulating fluidized bed(CFB) boiler for unit no.4 in Shijiazhuang Chengfeng Thermal Power Co Ltd had been seriously worn-out.The causes resulting in worn-out of the air cap for said boiler have been analysed
and corresponding technical retrofit being carried out.Results of test show that the resistance of empty plate after retrofitting the air cap has been reduced
the air distribution being uniform
and the fluidizing state being good;annually saved electricity being valued at about 0.119 million yuan
saved coal being worth 0.089 million yuan
and saved expenses for replacing spare parts of the air cap hitting about 0.049 million yuan