DESIGN OPTIMIZATION OF DIRECT AIR COOLING UNIT AND ANALYSIS ABOUT INFLUENCE OF AMBIENT TEMPERATURE VARIATION UPON ECONOMIC EFFICIENCY IN UNIT'S OPERATION
LIANG Bo, TANG Sheng-liChongqing University. DESIGN OPTIMIZATION OF DIRECT AIR COOLING UNIT AND ANALYSIS ABOUT INFLUENCE OF AMBIENT TEMPERATURE VARIATION UPON ECONOMIC EFFICIENCY IN UNIT'S OPERATION[J]. Thermal power generation, 2008, (5): 6-9.
DOI:
LIANG Bo, TANG Sheng-liChongqing University. DESIGN OPTIMIZATION OF DIRECT AIR COOLING UNIT AND ANALYSIS ABOUT INFLUENCE OF AMBIENT TEMPERATURE VARIATION UPON ECONOMIC EFFICIENCY IN UNIT'S OPERATION[J]. Thermal power generation, 2008, (5): 6-9. DOI: 10.19666/j.rlfd.2008.05.002.
DESIGN OPTIMIZATION OF DIRECT AIR COOLING UNIT AND ANALYSIS ABOUT INFLUENCE OF AMBIENT TEMPERATURE VARIATION UPON ECONOMIC EFFICIENCY IN UNIT'S OPERATION
摘要
提出了直接空冷系统优化设计的参数和优化目标函数
并对某台600 MW直接空冷机组进行了优化设计。根据直接空冷机组的传热方程
定量分析了环境温度变化对机组运行经济性的影响
结果表明环境温度变化对机组运行经济性影响较大
对此
提出了控制风机群运行状态以达到经济运行的目的。
Abstract
The design optimization parameters and optimizing object function of the directing air cooling unit have been put forward
and design optimization of a 600 MW direct air cooling unit being carried out.The influence of ambient temperature variation upon the economic efficiency in operation of the unit has been quantitatively analysed on the basis of heat transfer equation for the direct air cooling unit
the results show that the ambien temperature variation has greater effect upon the economic efficiency in operation of the unit
hence a scheme of controlling the running state of fan groups being put forward for reaching the target of economic operation.
CALCULATION AND ANALYSIS OF CHARACTERISTICS UNDER OFF-DESIGN CONDITION OF DIRECT AIR COOLING SYSTEM FOR AIR COOLING UNITS
STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
ANALYSIS OF “UNSYMMETRIC BURNING” PROBLEM IN A W-SHAPED FLAME BOILER OF 600 MW UNIT
CONTROL STRATEGY OF SUPERCRITICAL ONCE-THROUGH BOILER FOR 600 MW UNITS
CAUSE ANALYSIS OF JAMMING AND AIR LEAKAGE OF THE HOT-AIR DAMPER AND RETROFIT THEREOF
Related Author
LI Gao-chao
ZHU Bao-tian
CHEN Sheng-li
PENG Na Xi'an Thermal Power Research Institute Co Ltd
RONG Zhao-yang
HAN Ji-wen Guodian Beilun Power Plant
MIAO Changxin
WANG Jianwei
Related Institution
Xi'an Thermal Power Research Institute Co., Ltd
Guodian Zhejiang Beilun Power Plant
Shandong Electric Power Research Institute
Liaocheng Power Plant
Zhejiang Electric Power Education and Training Center