您当前的位置:
首页 >
文章列表页 >
ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS
更新时间:2025-09-28
    • ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS

    • Thermal Power Generation   Issue 4, Pages: 47-49(2008)
    • DOI:10.19666/j.rlfd.2008.04.012    

      CLC: TK229.2
    • Published:2008

    移动端阅览

  • GU ShanGuodian Changzhou Power Plant. ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS[J]. Thermal power generation, 2008, (4): 47-49. DOI: 10.19666/j.rlfd.2008.04.012.

  •  
  •  

0

Views

212

下载量

5

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER
ESTABLISHMENT OF SERVICE LIFE MANAGEMENT SYSTEM FOR HIGH-TEMPERATURE BOILER TUBES IN THERMAL POWER PLANT BASED ON B/S STRUCTURE
TEST STUDY ON CONTROLLING HEAT DEVIATION IN UTILITY BOILERS BY USING JET-FLOW READJUSTING METHOD
SEVERAL PROBLEMS EXISTING IN OPERATION OF SUPERCRITICAL AND ULTRA-SUPERCRITICAL BOILERS
INFLUENCE OF OXYGEN TREATMENT FOR SUPERCRITICAL UNITS UPON FORMATION AND PEEL-OFF OF OXIDE SKIN

Related Author

LIU Tong
XU Gang
DU Bao-hua
LI Yao-jun
LIU Zhen-yu
LI Chung-min
WANG Zhong-jie
SUN Xi(Xi'an Thermal Power Reseach Institute Co.Ltd

Related Institution

North China Electric Power University
North China Electric Power University Beijing
Xi'an Thermal Power Research Institute Co., Ltd
School of Power Engineering, Nanjing University of Science and Technology
0