ZHENG Shou-zhong1, LI Qian-jun21.China National Water Resources & Electric Power Matirials and Equipment Tianjin Company. NUMERICAL SIMULATION AND TEST OF GAS-PHASE FIELD IN SPOUTING BED/SPOUTING FLUIDIZED BED HAVING BEEN IMPROVED ON THE BASIS OF LATTICE[J]. Thermal power generation, 2008, (4): 18-21.
DOI:
ZHENG Shou-zhong1, LI Qian-jun21.China National Water Resources & Electric Power Matirials and Equipment Tianjin Company. NUMERICAL SIMULATION AND TEST OF GAS-PHASE FIELD IN SPOUTING BED/SPOUTING FLUIDIZED BED HAVING BEEN IMPROVED ON THE BASIS OF LATTICE[J]. Thermal power generation, 2008, (4): 18-21. DOI: 10.19666/j.rlfd.2008.04.005.
NUMERICAL SIMULATION AND TEST OF GAS-PHASE FIELD IN SPOUTING BED/SPOUTING FLUIDIZED BED HAVING BEEN IMPROVED ON THE BASIS OF LATTICE
Some asymmetric phenomena usually occur when using FLUENT software to numerically simulate such strictly axisymmetric column-cone objects as spouting bed and spouting fluidized bed
the pseudo-convergence and pseudo-diffusion of commonly occurred gas-phase field has also phenomenon of asymmetric flow field.From view point of the lattice structure
an improvement of the lattice has been put forward to adopt non-consistent lattice and increase the density of lattice along the axial direction of column and in the area corresponding to size of the cone inlet.Based on the improvement of lattice
numerical simulation of the gas-phase field for spouting bed and spouting flurdized bed has been carried out
and test of simulated results being made in the corresponding test system.The result shows that the improvement of lattice is feasible
and has better universality for the column-cone objects.