CAUSE ANALYSIS FOR STALL OF AXIAL FANS OPERATING IN PARALLEL
The stall of a forced draft fan and a primary air fan for boiler no.2 in one power plant has been analysed.Through test and inspection
it was found that the main cause leading to stall of the forced draft fan is reversely installed the outlet guide blades
and that leading to stall of the primary air fan is most higher ventilation resistance and most higher outlet temperature of the coal pulveri-zer.After retrofitting
no stall appears again on the said forced draft fan and the primary air fan.