CHEN Lu North-west China Electric Power Construction and Debugging Research Institute. CONTROL OF DRUM-WALL TEMPERATURE DIFFERENCE ON LARGE-CAPACITY BOILERS[J]. Thermal power generation, 2008, (1): 75-77.
DOI:
CHEN Lu North-west China Electric Power Construction and Debugging Research Institute. CONTROL OF DRUM-WALL TEMPERATURE DIFFERENCE ON LARGE-CAPACITY BOILERS[J]. Thermal power generation, 2008, (1): 75-77. DOI: 10.19666/j.rlfd.2008.01.018.
CONTROL OF DRUM-WALL TEMPERATURE DIFFERENCE ON LARGE-CAPACITY BOILERS
摘要
分析了汽包壁温差产生的原因
从机组起动、升温升压、正常运行、停炉过程几方面提出了有效防止汽包壁温差增大的措施。通过采取这些措施
可以有效控制汽包壁温在合适的范围
保证机组的安全稳定运行。
Abstract
The causes leading to drum-wall temperature difference have been analysed
and measures for effectively preventing the increase of drum-wall temperature difference being put forward from several aspects
such as start-up of unit
raising temperature and pressure
in normal operation
in process of shut-down etc..Through adoptation of said measures
the drum-wall temperature difference can be effectively controlled into a suitable range