WANG Hong-yu1, CHEN Xin-yu2, CHEN Hua-chun3, et al. COMPARISON OF PRESSURE-STABILIZING METHOD AND PRESSURE-REDUCING METHOD FOR STEAM BLOWING BOILER OF SUPERCRITICAL UNITS[J]. Thermal power generation, 2008, (1): 72-74.
DOI:
WANG Hong-yu1, CHEN Xin-yu2, CHEN Hua-chun3, et al. COMPARISON OF PRESSURE-STABILIZING METHOD AND PRESSURE-REDUCING METHOD FOR STEAM BLOWING BOILER OF SUPERCRITICAL UNITS[J]. Thermal power generation, 2008, (1): 72-74. DOI: 10.19666/j.rlfd.2008.01.017.
COMPARISON OF PRESSURE-STABILIZING METHOD AND PRESSURE-REDUCING METHOD FOR STEAM BLOWING BOILER OF SUPERCRITICAL UNITS
The situation of steam blowing by using pressure-stabilizing method and pressure-reducing method under condition without putting out the fire in debugging process of boiler no.4 for supercritical unit in Huaneng Taicang Power Generation Co Ltd has been presented.Practice in blowing shows that the required pipe-blowing coefficient and blowing quality can be ensured no matter what method is used for steam blowing
however
the effectiveness of pressure-reducing method under condition without putting out the fire is superior than that of pressure-stabilizing method