ZHANG Chu-fang, DANG LongHudian Pucheng Power Generation Co Ltd. DIAGNOSIS OF ECONOMIC EFFICIENCY FOR SPRAYING WATER DESUPERHEATING OF UNIT NO.3 BY USING THE EQUIVALENT ENTHALPY DROP METHOD[J]. Thermal power generation, 2007, (12): 4-7.
DOI:
ZHANG Chu-fang, DANG LongHudian Pucheng Power Generation Co Ltd. DIAGNOSIS OF ECONOMIC EFFICIENCY FOR SPRAYING WATER DESUPERHEATING OF UNIT NO.3 BY USING THE EQUIVALENT ENTHALPY DROP METHOD[J]. Thermal power generation, 2007, (12): 4-7. DOI: 10.19666/j.rlfd.2007.12.002.
DIAGNOSIS OF ECONOMIC EFFICIENCY FOR SPRAYING WATER DESUPERHEATING OF UNIT NO.3 BY USING THE EQUIVALENT ENTHALPY DROP METHOD
The thermal system of N330-17.75/540/540 type steam turbine for unit no.3 in second-phase project of Huadian Pucheng Power Generation Co Ltd has been analysed. On the basis of test data under three typical operating conditions
i.e. 300 MW
260 MW
and 165 MW
the economic efficiency of excessive desuperheating water flow in the superheater and reheater has been quantitatively calculated. Results show that the excessive desuperheating water flow in the superheater and reheater makes the standard coal consumption to increase maximally up to 2.57 g/kW·h. After adjustment of the related equipments
the standard coal consumption has been decreased to 2.06 g/kW·h.