国产亚临界600MW机组各项运行技术指标与同类型进口机组相差较大
机组热经济性较差。结合某台国产600MW机组的实际运行数据
阐述汽轮机组热经济性分析的一般方法
分析影响机组热经济性的主要因素
提出相应的节能降耗措施。
All technical indices in operation of home-made subcritical 600 MW units are comparatively inferior to those of imported units of the same kind
and the thermal economic efficiency of home-made units being lower. Combined with concrete data of one home-made 600 MW unit
the general method of analysing thermal economic efficiency for steam turbine unit has been expounded
the main factors affecting the thermal economic efficiency being analysed
and the corresponding measures for energy-saving and for consumption-reducing being put forward.