HU Lin-ming1, LONG Hui-guo2, LI Guang21.Hunan Provincial Electric Power Testing & Research Institute. CAUSE ANALYSIS OF TUBE-BURST IN LOW-TEMPERATURE REHEATER[J]. Thermal power generation, 2007, (11): 84-86.
DOI:
HU Lin-ming1, LONG Hui-guo2, LI Guang21.Hunan Provincial Electric Power Testing & Research Institute. CAUSE ANALYSIS OF TUBE-BURST IN LOW-TEMPERATURE REHEATER[J]. Thermal power generation, 2007, (11): 84-86. DOI: 10.19666/j.rlfd.2007.11.023.
CAUSE ANALYSIS OF TUBE-BURST IN LOW-TEMPERATURE REHEATER
摘要
通过宏观检查与显微组织分析
分析了某电厂1021t/h锅炉运行不足1年低温过热器爆管泄漏产生的原因
认为人孔门保温不严
造成人孔门附近管排局部发生严重飞灰磨损
是导致低温再热器爆管的主要原因
对此
提出了相应的处理措施。
Abstract
Through macroscopic examination and microstructure analysis
the causes leading to tube-burst in low-temperature reheater of a 1021 t/h boiler during operation in a period less than one year have been analysed
and disposal measures being put foreard. Result of analysis shows that the main cause resulting in tube-burst of low-temperature reheater is as follows: the thermal insulation of manhole gate is not perfect
making the tube-row near the manhole gate to suffer locally serious fly ash wornout.