WANG Zhi-gang, ZHANG Guang-cai, WANG Chun-chang, et al. CAUSE ANALYSIS OF LOAD BEING LIMITED FOR ONE BOILER[J]. Thermal power generation, 2007, (11): 45-47.
DOI:
WANG Zhi-gang, ZHANG Guang-cai, WANG Chun-chang, et al. CAUSE ANALYSIS OF LOAD BEING LIMITED FOR ONE BOILER[J]. Thermal power generation, 2007, (11): 45-47. DOI: 10.19666/j.rlfd.2007.11.012.
CAUSE ANALYSIS OF LOAD BEING LIMITED FOR ONE BOILER
摘要
某电厂一台锅炉因主蒸汽和对流过热器管壁超温、减温水无裕量长期不能带满负荷。对此
通过分析和试验调整
在燃用两种煤条件下均可带满负荷运行。
Abstract
Because of over-temperature of the main steam and the tube-wall of convection superheater
as well as the desuperheating water is not abundant
a boiler in one power plant can’t carry full load in operation for a long term. Through adjustment test
the operation mode has been adjusted
making the boiler can carry full load in operation under condition of burning two coal sorts.