ZHAO Yong-ning1, LIU Fang-zhu2, LIU Tian-zuo31.Shandong Electric Power Research Institute. STUDY ON SERVICE LIFE OF X20CrMoWV121 MAIN STEM PIPE AFTER LONG-TERM OPERATION[J]. Thermal power generation, 2007, (10): 72-75.
DOI:
ZHAO Yong-ning1, LIU Fang-zhu2, LIU Tian-zuo31.Shandong Electric Power Research Institute. STUDY ON SERVICE LIFE OF X20CrMoWV121 MAIN STEM PIPE AFTER LONG-TERM OPERATION[J]. Thermal power generation, 2007, (10): 72-75. DOI: 10.19666/j.rlfd.2007.10.021.
STUDY ON SERVICE LIFE OF X20CrMoWV121 MAIN STEM PIPE AFTER LONG-TERM OPERATION
摘要
通过蠕变断裂试验和持久强度试验
研究125 MW机组长期运行后X20Cr Mo WV121钢主蒸汽管的蠕变变形方程和蠕变曲线
并根据持久强度外推法和θ函数法进行剩余寿命评估。结果表明
所研究的主蒸汽管道在以蠕变为主要失效模式下
满足继续安全运行10万h的要求。
Abstract
Through creep rupture test and endurance strength test
the creep deformation equation and creep curve of X20CrMoWV121 steel main steam pipe for a 125 MW unit after long-term operation have been studied
and the residual service life being evaluated on the basis of persistent strength extrapolation method and zero function method.Results show that the main steam pipe can satisfy the requirements of continuous safe operation for 100 000 h under condition of taking creep as the main failure mode.
EVALUATION OF MICROSTRUTURE PROPERTY FOR 10CrMo910 MAIN STEAM PIPING NO.1 OF UNIT NO4 IN NIANGZIGUAN POWER PLANT
应用老化因子方法评估高温部件的状态和寿命
HEAT-STRESS COUPLED NONLINEAR ANALYSIS AND LOW CYCLE FATIGUE DAMAGE EVALUATION OF TURBINE ROTORS
APPLICATION OF THICKNESS-DETECTING TECHNOLOGY FOR OXIDE-SCALE ON INNER SIDE OF TUBES TO PREVENT HIGH-TEMPERATURE SUPERHEATER IN A BOILER FROM TUBE-BURSTING
DEVELOPMENT AND APPLICATION OF SERVICE-LIFE MANAGEMENT TECHNOLOGY FOR IMPORTANT PARTS OF THERMAL POWER PLANTS
Related Author
肖学柱
王志武
陈露贵
任爱
李耀君
郭乙木
许平聪
黄丹
Related Institution
Wuhan University
Suzhou Thermal Power Research Institute
陕西西安710032
State Power Corporation Thermal Research Institute