YANG Hai-sheng1, GUO Jiang-long1, SONG Zi-shun2, et al. APPLICATION OF RAPID COOLING SYSTED BASED ON VACCOM METHOD FOR STEAM TURBINE OF 600MW UNIT[J]. Thermal power generation, 2007, (10): 38-40.
DOI:
YANG Hai-sheng1, GUO Jiang-long1, SONG Zi-shun2, et al. APPLICATION OF RAPID COOLING SYSTED BASED ON VACCOM METHOD FOR STEAM TURBINE OF 600MW UNIT[J]. Thermal power generation, 2007, (10): 38-40. DOI: 10.19666/j.rlfd.2007.10.011.
APPLICATION OF RAPID COOLING SYSTED BASED ON VACCOM METHOD FOR STEAM TURBINE OF 600MW UNIT
摘要
通过对邯峰发电公司660 MW机组汽轮机的结构分析
介绍了其采用的真空法快速冷却(快冷)系统
并将真空法快冷与常用的加热压缩空气法快冷进行了比较。实践证明
真空快冷系统的应用较为安全可靠。
Abstract
Through structure analysis of steam turbine for the 600 MW unit in Hanfeng Power Generation Co Ltd
a rapid cooling system based on vacuum method has been presented
and a comparison of the said system with the commonly used system
in which the heated compressed air is taken as the cooling medium
being carried out.Practice shows that the application of rapid cooling system based on vacuum method to be safe and reliable.
SIMPLIFIED FINITEELEMENT CALCULATION MODEL OF TEMPERATURE FIELD FOR STEAM TURBINE ROTOR
APPLICATION OF SOLID SELF-LUBRICATING TECHNOLOGY IN POWER PLANTS
STUDY ON CONTROL SYSTEM SETTING OF DOUBLE EXTRACTION ADJUSTABLE STEAM TURBINE
ANALYSIS OF FAULTS OCCURRED IN SYNCHRONIZATION WITH POWER NETWORK FOR TAKING INITIAL LOAD BY STEAM TURBINE OF A 180MW GAS AND STEAM TURBINE COMBINED CYCLE UNIT
CAUSE ANALYSIS AND IMPROVEMENT MEASURES FOR PRESSURE REDUCTION OF LUBRICANT OIL DURING STARTUP OF 300MW UNITS