ZHAO Yan-ping, WANG Gui-mingShandong Elextric Power Research Institute. ANALYSIS OF PROBLEMS EXISTING IN FLAME-OUT PROTECTION OF BOILERS AND APPROACH TO MEASURES FOR ENHANCING ITS RELIABILITY[J]. Thermal power generation, 2007, (7): 56-58.
DOI:
ZHAO Yan-ping, WANG Gui-mingShandong Elextric Power Research Institute. ANALYSIS OF PROBLEMS EXISTING IN FLAME-OUT PROTECTION OF BOILERS AND APPROACH TO MEASURES FOR ENHANCING ITS RELIABILITY[J]. Thermal power generation, 2007, (7): 56-58. DOI: 10.19666/j.rlfd.2007.07.015.
ANALYSIS OF PROBLEMS EXISTING IN FLAME-OUT PROTECTION OF BOILERS AND APPROACH TO MEASURES FOR ENHANCING ITS RELIABILITY
Through analysis of the relationship between furnace pressure and flame-out in the boiler
the hidden danger in safe operation of boiler due to the flame-out protection of boiler delayed after the furnace-pressure protection control has been pointed out.An approach to the reliability of the flame-out protection in boiler has been carried out
giving out an improvement scheme for the control logic of flame-out protection in boiler.