CAUSE ANALYSIS OF DESUPERHEATER FRACTURE FOR BOILER OF 600 MW UNIT
The causes leading to desuperheater fracture of boiler's superheater for 600 MW unit of one power plant have been analysed
it is believed that the main causes are as follows: large temperature difference between wall temperature of leading-in pipe and that of atomizing tube for the desuperheating water
welding defects of the inlet tube socket with the inlet tube of desuperheater
as well as malpractice existing in weldjoint of different steels for the atomizing tube and the inlet tube etc..For these
measures such as changing the quality of materials
decreasing the thickness of tube-wall
improving the welding technology and the detecting method etc.have been put forward.After implementation
vibration and other abnormalities of the desuperheating water pipeline have never occurred again