介绍了大唐洛阳首阳山发电厂1号锅炉出现的典型锅炉“四管”爆漏情况
对爆漏原因进行了分析和处理
提出了相应的预防措施。实施后
“四管”爆漏现象已基本控制
提高了锅炉的健康水平。
Abstract
The situation of burst-leakage from "Four tube kinds" of boiler appeared on boiler no.1 in Datang Luoyang Shouyangshan Power Plant has been presented
and the causes leading to burst-leakage being analysed